<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="4196">
 <titleInfo>
  <title>Development of an Absolute Calibration System for Nondestructive Testing Devices</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Briggs,  Robert C.</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text"></placeTerm>
  </place>
  <publisher>TRB</publisher>
  <dateIssued>1991</dateIssued>
 </originInfo>
 <language>
  <languageTerm type="code">en</languageTerm>
  <languageTerm type="text">English</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Computer Software</form>
  <extent>p24-30</extent>
 </physicalDescription>
 <relatedItem type="series">
  <titleInfo/>
  <title>Trr No. 1293 Pavement Design, Management, And Performance</title>
 </relatedItem>
 <note>Trr No. 1293 Pavement Design, Management, And Performance, pp. 24-30&#13;
Geophones were selected for the calibration of the FW I) sensors after an evaluation of the accuracy and precision oti five candidate sensors. An aluminum loading plate was constructed to allow mounting of the load cells in line with and below the FWll load cell. The calibration curves of all load cells were traceable to the National Bureau of Standards. The effects on the calibration factors of load cells of using the aluminum plate were small. The signal-conditioning unit was developed to condition the signals before acquisition. The system was used to calibrate an FWD device. The system was effective. A calibration process is proposed on the basis of an analysis of the data collected. The calibration system is cost-effective, accurate, and rugged, and it can be used b_v highway agencies to calibrate their FWD devices.</note>
 <subject authority="">
  <topic>PAVEMENT TESTING</topic>
 </subject>
 <classification>625.7(047.31)</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>Perpustakaan Direktorat Bina Teknik Jalan dan Jembatan Direktorat Jenderal Bina Marga - Kementerian Pekerjaan Umum (NPP: 3273244A00000001)</physicalLocation>
  <shelfLocator></shelfLocator>
  <holdingSimple>
   <copyInformation>
    <numerationAndChronology type="1">0000004422</numerationAndChronology>
    <sublocation>My Library</sublocation>
    <shelfLocator></shelfLocator>
   </copyInformation>
  </holdingSimple>
 </location>
 <recordInfo>
  <recordIdentifier>4196</recordIdentifier>
  <recordCreationDate encoding="w3cdtf"></recordCreationDate>
  <recordChangeDate encoding="w3cdtf"></recordChangeDate>
  <recordOrigin>machine generated</recordOrigin>
 </recordInfo>
</mods>
</modsCollection>