<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="20889">
 <titleInfo>
  <title>PTI  Anchorage Zone Design</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Wollmann, Gregor P</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <name type="Personal Name" authority="">
  <namePart>Roberts, Carin L</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text">Phoenix</placeTerm>
  </place>
  <publisher>Post tensioning institute</publisher>
  <dateIssued>2000</dateIssued>
 </originInfo>
 <language>
  <languageTerm type="code">en</languageTerm>
  <languageTerm type="text">English</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Text</form>
  <extent>46 p.</extent>
 </physicalDescription>
 <relatedItem type="series">
  <titleInfo/>
  <title>Post-tensioning manual, sixh edition</title>
 </relatedItem>
 <note>Post-tensioning of concrete requires the introduction of large, concentrated tendon forces into structures. To appreciate the magnitude of these forces, consider a typical bridge tendon with 19-152 mm (0.6 in.) strands. The jacking force for such a tendon may reach close to 4,000 kN (900 kips). This is equivalent to the weight of twelve HS 20-44 trucks Often several long tendons are anchored in a closely spaced group (Fig. VIII-2). A significant amount of spring energy is stored in such tendon groups which would be released suddenly in case of tendon anchorage failure. As an example, the spring energy stored in four 19-152 mm strand tendons of 200 In length istheoretically sufficient to launch an HS 20-44 truck over a seven-story building.&#13;
LOKASI: Rak Penelitian 2&#13;
(Kode: PTI-011)</note>
 <note type="statement of responsibility"></note>
 <subject authority="">
  <topic>TENDONS</topic>
 </subject>
 <classification>624.21.095.3 (047.31)</classification>
 <identifier type="isbn">1931085013</identifier>
 <location>
  <physicalLocation>Perpustakaan Direktorat Bina Teknik Jalan dan Jembatan Direktorat Jenderal Bina Marga - Kementerian Pekerjaan Umum (NPP: 3273244A00000001)</physicalLocation>
  <shelfLocator>624.21.095.3 (047.31) WOL a</shelfLocator>
  <holdingSimple>
   <copyInformation>
    <numerationAndChronology type="1">0000021397</numerationAndChronology>
    <sublocation>My Library</sublocation>
    <shelfLocator>624.21.095.3 (047.31) PTI a</shelfLocator>
   </copyInformation>
  </holdingSimple>
 </location>
 <slims:image>PTI1.jpg.jpg</slims:image>
 <recordInfo>
  <recordIdentifier>20889</recordIdentifier>
  <recordCreationDate encoding="w3cdtf">2016-09-09 11:36:34</recordCreationDate>
  <recordChangeDate encoding="w3cdtf">2022-08-22 09:46:36</recordChangeDate>
  <recordOrigin>machine generated</recordOrigin>
 </recordInfo>
</mods>
</modsCollection>